The SINEAX V624 converts measured quantities (i.e. signal from a thermocouple
or a resistance thermometer) into a proportional, analog output quantity.
- Measurement inputs for sinusoidal, square-wave or distorted nominal input voltages with dominant fundamental wave
- Generator and bus bar input voltage: 10 to 690 V
- Nominal input frequency: 50 Hz
- Auxiliary power: 85 to 230 V AC/DC
- Input frequency response time periods: 4
- Measuring range limits: ± 10° to < ± 180° el
- Measurement output available with unipolar, bipolar or live-zero output quantities
- Measuring method: acquires distance between zero-crossings
- Power supply: integrated AC-DC power pack with large tolerance range for universal use
- Standard GL (Germanischer Lloyd) / suitable for use on ocean-going vessels
- Housing: P13/70 housing for top-hat rail mounting
- CSA certificate, German Lloyd approval